Foxy® R1

The one-rack Foxy R1 fraction collector can be adapted to a broad spectrum of applications. The units can distribute fractions into 96 well microplates, standard tube sizes, and bottles. For essentially unlimited volumes, funnel racks can direct fluids to any collection vessel or downstream process.

Standard Features

  • - Collect peaks of interest separately using any combination of slope, level, and time window reliably separates peaks by monitoring detector output, so you don’t have to expend glassware on no-interest effluent
  • - Collect uniform fractions by time, drop count, or pumped volume
  • - Stores up to 8 collection methods
  • - Choice of available racks (specify when ordering).
  • - Coldroom-friendly design
  • - Sturdy cast aluminum frame
  • - Easy to use symbolic touch screen interface
  • - Built-in Ethernet and RS-232 communication capabilities
  • - Faster tube changes
  • - µL delay volume between diverter valve and drop former


Foxy® R2 and Foxy® R2 High Flow

The two-rack Foxy R2 fraction collector can be adapted to a broad spectrum of applications. The units can distribute fractions into 96 well microplates, standard tube sizes, and bottles. For essentially unlimited volumes, funnel racks can direct fluids to any collection vessel or downstream process.

The Foxy R2 fraction collector uses two racks with radio frequency identification (RFID) to automatically detect collection racks for easy setup.


Standard Features

  • - Collect peaks of interest separately using any combination of slope, level, and time window reliably separates peaks by monitoring detector output, so you don't have to expend glassware on no-interest effluent
  • - Collect uniform fractions by time, drop count, or pumped volume
  • - Stores up to 8 collection methods
  • - Choice of available racks (specify when ordering).
  • - Coldroom-friendly design
  • - Sturdy cast aluminum frame
  • - Easy to use symbolic touch screen interface
  • - Built-in Ethernet and RS-232 communication capabilities
  • - Faster tube changes
  • - µL delay volume between diverter valve and drop former


Specifications

Flow Rate Range 5 - 200 mL/min (Flash & Prep)
Pump Prime Self-priming
Maximum Pressure (Flash operation) 200 psi (13.8 bar)
Maximum Pressure (Prep operation) 3,500 psi (240 bar)
UV and UV-Vis Detection UV 200-400 nm (standard); UV-Vis 200-800 nm (optional)
ELSD Detection Built-in ELSD detector compatible with UV or UV-Vis
Mass Spectrometer Three models with mass ranges of 10-1,200 and 10-2,000 Da
Programmable gradients Linear, step, isocratic
Sample introduction (Flash) Solid or liquid load
Sample introduction (Prep) Variable volume liquid load (5mL loop standard)